Specification:
The instrument is composed of tester and temperature controller.Standard water value: 51±1 s (Water temperature 20±0.1 ℃; 200 ml; It can be converted into water value at 25±0.1 ℃, 50 ml)
Temperature measurement range: 0℃~100℃
Temperature controlling accuracy: ±0.1℃
Thermometer: In accordance with T0622
Measuring flask: 100 ml
Inner container: Made of stainless steel
Power of heater: 550 W
Timer accuracy: 1/100 s
Specification:
Accommodates six sample beakers.
Microprocessor temperature control with digital display and over temperature protection
Testing Capacity: Six (6) 400mL sample beakers
Maximum Temperature: 104C (220F)
Heater Range: 0-1500W
Drive Motor: explosion proof ball bearing type
Specification:
Our complete range of color comparators are developed by our experts following the market standards by utilizing finest products and innovative technology.
These color comparators are demanded in the industry for their superb attributes.
Ease of use
Maintenance free
Perfect finish
Specification:
Gum formed during fuel storage can deposit on induction system surfaces, intake valves, stems and guides. To test for gum content, a 50mL sample is evaporated in an aluminum block bath for a specified period under controlled conditions of
temperature and flow of air (aviation and motor gasolines) or steam (aircraft turbine fuel).
Specification:
For determining the Saybolt Viscosity of pertoleum products within 70°-210°F temperature range and Saybolt Furol Viscosity of bituminous materials within 250°-450°F temperature range.
The equipment consists of a cylindrical cup, a Universal Tip, a Furol Tip, a stirrer, a receiving flask, a filter funnel, a withdrawal tube, a thermometer support, a bath fitted with an immersion heater and an auto-transformer.
Suitable for operation on 220V, 50 Hz, Single phase supply.
Specification:
Dumbbell specimens made by vulcanized rubber, put them inside chamber
and as per different materials characteristics, standards suggest to choose
70/100/120℃, time can choose 24/48/96/168 and so on ,various conditions to
proceed with rubber aging. Compare the tension strength and elongation change before and after aging.
Specification:
Flow cups are designed to accurately measure the viscosity of paints, inks, varnishes and similar products. The process of flow through an orifice
can often be used as a relative measurement and classification of viscosity.
Specification:
Flask Sulphonation is lab glass or plasticware used to prepare a solution. It is used to make up a solution to a known volume. Volumetric flasks are used to measure volumes much more precisely than beakers or Erlenmeyer flasks. Flask Sulphonation with neck graduated 0 to 10 ml.
and figured 0 to 100% for determination of olefin plus aromatic content.
Specification:
Weight 1.5 Grams (g)
Color Black and Silver
Length 5.5 Centimeter (cm)
Height 300 Centimeter (cm)
Material Mild Steel
Display Type Analog And Digital
Specification:
Floor standing support with rod and clamps for sustain glassware and elements.
Upper part composed by 380 W heating belt, boiling flask 1000 ml capacity with lateral sample injector port, upper condenser 300 mm.
Gravity drain system with top manual actuator.
Stainless steel hood with fume recovery system, complete with filter holder and o-rings that avoid pressure leak.
3 × needle valve for deviating fluid / nitrogen flush and recovery program.
Lower flask 500 ml with temperature sensing port.
Lateral condenser for fume recovery.
Lower flask with condenser for solvent recovery.
Lower heating mantle 250 W for boiling solvent, equipped with up/down movement.
External control unit with Linetronic software to manage the temperature inside the 2 heating part of instrument, timer for analysis, audible alarm and analysis wizard step-by-step.
Instrument shipped with spare o-rings, 1 pack of 100 filters and allen keys for open easily the hood for cleaning and filter change.
Specification:
Foaming of lubricating oils in applications involving turbulence, high speed gearing or high volume pumping can cause inadequate lubrication, cavitations, overflow and premature oxidation. The sample is blown with a controlled volume of air at different specified temperatures, including a newer high temperature test at 150°C. The resultant foam is measured at the end of each aeration period and at different intervals afterward. In the high temperature test, the amount of
time required for the foam to collapse to “0” after the aeration period is also measured.
Specification:
Measures the vapor pressure of automobile and aviation gasoline, petroleum products and crude oils.
Conforms to ASTM D323, D1267 and related specifications
RVP bath provides high accuracy programmable temperature control
Vapor pressure is a critical factor in the handling and performance of liquid petroleum and liquefied petroleum gas products.
RVP Bath controls temperature with ±0.2°F (±0.1°C) precision, and determines vapor pressure of gases by immersion of vapor pressure cylinders at the proper depth per ASTM specifications. Dual LED displays provide actual and set-point temperature values in °F/°C format. Holds up to four pressure cylinders. Bath is made of a double-wall construction with fiberglass insulated
stainless steel tank. A sturdy 1′ (25mm) flange permits flush-mount bench-top installation for easy access to the bath interior.
2) RVP Gauges have a large easy-to-read 4-1/2″ (11.4 cm) diameter dial. Accurate to ±0.5% of scale range. Gauges feature an aluminum case with brass handle, blow-out back, and 1/4″ NPT(M) connection. Sold separately.
3) RVP Cylinders have polished stainless steel construction. Use one-opening cylinder to test gasoline and other products having a vapor pressure below 26 psi. Two-opening cylinder is for liquid petroleum products and liquefied petroleum gas products (LPG) with a vapor pressure above 26 psi. The two-opening cylinder includes straight-through ball valve and a needle valve. For LPG testing, order the bleeder valve assembly for use with the two-opening cylinder. Sold separately.
© 2023. All rights reserved. Designed by SKC Infotech