image

Aniline Point

Specification:
Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate.

image

Bomb Calorimeter apparatus

Specification:
The bomb calorimeter is a laboratory instrument used to measure the amount of a sample's combustion heat or heat power when excess oxygen combustion occurs. The purpose of this research is to determine the effect of using the bomb calorimeter on the ability of physics students to process science

image

Abel Flash Point

Specification:
Abel Flash Point Apparatus is suitable for determining the close cup flash point of Petroleum and mixtures according to IP 33 & IP 170 and also IS 1448 (Part I) 1985 (P:20). It is suitable for oils whose flashes below 70°C.

image

Distillation apparatus

Specification:
The distillation apparatus, commonly called a 'still', consists of a vessel for plant material and water, a condenser to cool and condense the vapour produced and a method of collection, or 'receiver'. Material from the appropriate part of the plant for extraction is immersed in water in the distillation vessel.

image

Pensky Martens flash Point

Specification:
The Pensky-Martens Flash Point Tester consists of a closed-cup test arrangement that contains any vapors produced and essentially simulates the situation in which a potential source of ignition is accidentally introduced into a container.

image

Acidity by extraction apparatus

Specification:
Consists of two sets of glassware mounted on a sturdy base/upright assembly with separate line switches, rheostats and condenser water control valves for each. Each glassware set includes 500mL boiling flask with heating tube, Hopkins reflux condenser with aspirator, thistle tube, 250W heating coil and 400mL Borosilicate Glass beaker.

image

Demulsification apparatus

Specification:
They are commonly used in the processing of crude oil, which is typically produced along with significant quantities of saline water.

image

Redwood Viscometer No.1 & No.2

Specification:
These viscometers are used to determine the viscosity of petroleum products. Two adoption of Red Wood viscometer are available No. 1 for liquids having Red Wood flow 20 seconds to 2000 seconds and No. 2 for liquids whose flow time exceeds 2000 seconds and No.

image

Adiabatic Bomb Calorimeter

Specification:
The adiabatic bomb calorimeter provides a safe, simple, and effec- tive means of measuring energies of combustion or many types of fuels, including food. Determination of calories in food, especially sugars and carbohydrates, is successfully accomplished via adiabatic calorimetry.

image

Emulsion Test Apparatus

Specification:
This test method covers measurement of the ability of petroleum oils or synthetic fluids to separate from water. Power Supply 230 Volts, 50 Hz, Single phase, AC Supply Voltage 230 Volt (v)

image

Romsbottom Carbon Residue

Specification:
Comprising of Coking furnace with 5 bulb wells, (4 each for cking bulbs and 1 for the control bulb). Temperature is accurately controlled and maintained by fully automatic solid state time proportional digital controller and thermocouple. Power supply 230 V, 1 Phase, 50 Hz.

image

Acidity Testing Kit of Transformer Oil

Specification:
Acidity Test of Transformer Insulating Oil Causes of Acidity in Insulating Oil. In insulating oil in the transformer may occasionally come into contact with air. It may be during opening any blanking or due to leakage in the oil tanks or in associated pipe lines. Because of that the oxidation reaction in the transformer oil takes place, which further be accelerated due to temperature and presence of catalysts like iron, copper and dissolved metallic compounds in the transformer oil.