Specification:
Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample
or sample plus n-heptane are stirred together while being heated at a controlled rate.
Specification:
The bomb calorimeter is a laboratory instrument used to measure the amount of a sample's combustion heat or heat power when excess oxygen combustion occurs. The purpose of this research is to determine the
effect of using the bomb calorimeter on the ability of physics students to process science
Specification:
Abel Flash Point Apparatus is suitable for determining the close cup flash point of Petroleum and mixtures according to IP 33 & IP 170 and
also IS 1448 (Part I) 1985 (P:20). It is suitable for oils whose flashes below 70°C.
Specification:
The distillation apparatus, commonly called a 'still', consists of a vessel for plant material and water, a condenser to cool and condense the vapour produced and a method of collection, or 'receiver'. Material from the appropriate
part of the plant for extraction is immersed in water in the distillation vessel.
Specification:
The Pensky-Martens Flash Point Tester consists of a closed-cup test arrangement that contains any vapors produced and essentially simulates the situation
in which a potential source of ignition is accidentally introduced into a container.
Specification:
Consists of two sets of glassware mounted on a sturdy base/upright assembly with separate line switches, rheostats and condenser water control valves for each. Each glassware set includes 500mL boiling flask with heating tube, Hopkins reflux condenser
with aspirator, thistle tube, 250W heating coil and 400mL Borosilicate Glass beaker.
Specification:
They are commonly used in the processing of crude oil,
which is typically produced along with significant quantities of saline water.
Specification:
These viscometers are used to determine the viscosity of petroleum products. Two adoption of Red Wood viscometer are available No. 1 for liquids having Red Wood flow 20
seconds to 2000 seconds and No. 2 for liquids whose flow time exceeds 2000 seconds and No.
Specification:
The adiabatic bomb calorimeter provides a safe, simple, and effec- tive means of measuring energies of combustion or many types of fuels, including food. Determination of calories in food, especially
sugars and carbohydrates, is successfully accomplished via adiabatic calorimetry.
Specification:
This test method covers measurement of the ability of petroleum oils or synthetic fluids to separate from water.
Power Supply 230 Volts, 50 Hz, Single phase, AC Supply
Voltage 230 Volt (v)
Specification:
Comprising of Coking furnace with 5 bulb wells,
(4 each for cking bulbs and 1 for the control bulb).
Temperature is accurately controlled and maintained by fully automatic solid state time proportional digital controller and thermocouple.
Power supply 230 V, 1 Phase, 50 Hz.
Specification:
Acidity Test of Transformer Insulating Oil Causes of Acidity in Insulating Oil. In insulating oil in the transformer may occasionally come into contact with air. It may be during opening any blanking or due to leakage in the oil tanks or in associated pipe lines. Because of that the oxidation reaction in the transformer oil takes place, which further be accelerated due to temperature and presence
of catalysts like iron, copper and dissolved metallic compounds in the transformer oil.